Air Cooled: for Process Cooling,
Front Discharge
Refrig : R-134A (CFC Free), R-407C (CFC Free), R-22
(Freon)
Capacity from 3.5 TR to 35 TR
Liquid Temperatures from Plus 3 to Plus 25 deg. C
Hermetic Scroll Comp. |
|
|
|
|
|
Air Cooled: for Process Cooling,
Top Discharge
Refrig : R-134A (CFC Free), R-407C (CFC Free), R-22
(Freon)
Capacity from 5 TR to 100 TR
Liquid Temperatures from Plus 3 to Plus 25 deg. C
Hermetic Scroll Comp. |
|
|
|
|
|
Air Cooled: for Air Conditioning,
Front Discharge
Refrig : R-134A (CFC Free), R-407C (CFC Free), R-22 (Freon)
Condenser with 3/8" inner grooved copper tube
Capacity from 3.5 TR to 35 TR
Hermetic Scroll Comp. |
|
|
|
|
|
Air Cooled: for Air Conditioning,
Top Discharge
Refrig : R-134A (CFC Free), R-407C (CFC Free), R-22 (Freon)
Condenser with 3/8" inner grooved copper tube
Capacity from 5 TR to 100 TR
Hermetic Scroll Comp. |
|
|
|
|
|
Water Cooled Scroll Chiller for Process Cooling
Refrig : R-134A (CFC Free), R-407C (CFC Free), R-22
(Freon)
Capacity from: 5 TR to 110 TR
Liquid Temp from Plus 3 to Plus 25 deg C
Hermetic Scroll Comp. |
|
|
|
|
|
Water Cooled Scroll Chiller for Air Conditioning
Refrig : R-134A (CFC Free), R-407C (CFC Free), R-22 (Freon)
Ultra efficient water cooled condenser
Capacity from: 5 TR to 110 TR
Hermetic Scroll Comp.
|
|
|
|
|
|
MRI Chillers, Air Cooled Front Discharge
CT, PET & MRI CHILLERS
Designed in collaboration with major medical OEM´s
Ready solutions for Siemens, GE & Philips MRI machines
Capacity from
3.5 to 34 TR with independent emergency circuit
|
|
|
|
|
|
MRI Chillers, Air Cooled Top Discharge
CT, PET & MRI CHILLERS
Designed in collaboration with major medical OEM´s
Ready solutions for Siemens, GE & Philips MRI machines
Capacity from
3.5 to 34 TR with independent emergency circuit
|
|
|
|
|
|
Scroll Chillers Flamingo Chillers giving you the best scope of Scroll Chillers, for example, Water Cooled Scroll Chiller, Industrial Scroll Chiller, Scroll Compressor Chiller and Industrial Scroll Chillers with viable & opportune conveyance. Look at the above extent cap matches your necessity or simply drop a line for our deals agent who will be glad to help you make the best choice from the above range.
Heat waves are becoming a fact of the current environment situations. Industries and offices install the majority of cooling solutions. Industries have enormous cooling systems installed that make the biggest of rooms cool in a matter of minutes. The power carried by these machines goes beyond the capability of air conditioning systems installed in homes. However, apart from all of that, there are many different kinds of compressors that make the process possible. The choice compressors can range between several types however the most common are the scroll and screw chillers for the relatively smaller cooling needs. Industries make use of both of them as per their needs. Advantages Outlined Easily There are many benefits availed by industries with the use of scroll chillers. During part load operations, happening in conditions of high ambience, they work significantly better than screw chillers. The sound levels are quite low, and it needs lower levels of current to start. There are lesser numbers of switchgear, and it has only three connections, oil equalizer, suction and discharge. The design is simpler which makes maintenance easier and multiple circuits allow partial shutdown too. It uses both air and water coolants to induce cooling in the compressor. There is hardly any difficulty in using these chillers making them an industry favorite. |
|